Barudan A08: Memory is Full or Design Memory Read Error
What it means
The control could not store or read a design because memory is full or the design file is damaged. The source says to delete designs first, then rename or replace the problem design, and reformat the internal CF card if no design will read.
This page is generated from a public source: Barudan America — XS/XY Error Messages. It is a starting point, not a substitute for the manual for your exact model.
This code is tagged memory, design. Browse all memory codes or all Barudan memory codes.
What the manual says to check
- Check to see if the memory is full first. Delete some designs if full.
- This could also be a problem reading a design into memory. Try renaming the problem design, or try reading another design that’s verified good.
- If no designs will read into memory, may need to reformat the internal CF memory card. Call tech support.
Not sure whether to keep going? Read when to call a technician or how to read a code.
One tap helps the next person with this code. No account, no email. You can add detail if you want; it is optional.
Add detail (optional)
No names, emails, or serial numbers, please.
Still down?
Send Barudan A08 to a technician. Tell us the model and what the machine is doing. We’ll reply with the next step: a remote check, a part, or someone who services your area.
No account. No charge to ask. If the machine is mid-order, say so in the notes.
Related Barudan codes
FAQ
What does Barudan A08 mean?
Barudan A08 means: The control could not store or read a design because memory is full or the design file is damaged. The source says to delete designs first, then rename or replace the problem design, and reformat the internal CF card if no design will read. It is an error code and should be cleared before production.
How do I clear Barudan A08?
Start with: Check to see if the memory is full first. Delete some designs if full. Then: This could also be a problem reading a design into memory. Try renaming the problem design, or try reading another design that’s verified good. Then: If no designs will read into memory, may need to reformat the internal CF memory card. Call tech support.
When should I call a technician for Barudan A08?
If the checks above do not clear the code, or if the fix involves a board, driver, motor, or replacement part, call a technician. Do not keep running production with an unresolved fault.
Corrections: if this page is wrong for your model, keep the source link and the model/serial number. The correction process is described in Method & disclaimer.