Barudan XS/XY series

Barudan D01: Needle Bar Not Locked

error needlesensor Updated 2026-11-18
Quick answer Barudan D01 means The needle bar did not reach the locked position for a colour change. The source points to the colour-change lock sensor or a mechanical bind; rotate the assembly by hand first, and do not force a bind. First check: Color Change Lock sensor is not engaged or not working properly.

What it means

The needle bar did not reach the locked position for a colour change. The source points to the colour-change lock sensor or a mechanical bind; rotate the assembly by hand first, and do not force a bind.

This page is generated from a public source: Barudan America — XS/XY Error Messages. It is a starting point, not a substitute for the manual for your exact model.

This code is tagged needle, sensor. Browse all needle codes.

What the manual says to check

  1. Color Change Lock sensor is not engaged or not working properly.
  2. Manually rotate the Color change assembly so the sensor plate engages the Lock sensor and retry.
  3. If still a problem look to see if the Sensor LED is working.
  4. If the Color Change assembly is in a bind or jammed, do not force.
  5. See Error D05 for possible binds.
When to call a technicianIf the code returns after the checks above, or the machine develops a new noise, vibration, or thread break, call a technician.

Not sure whether to keep going? Read when to call a technician or how to read a code.

Repair deskNo. ______

Still down?

Send Barudan D01 to a technician. Tell us the model and what the machine is doing. We’ll reply with the next step: a remote check, a part, or someone who services your area.

Request a repair callback →

No account. No charge to ask. If the machine is mid-order, say so in the notes.

Related Barudan codes

FAQ

What does Barudan D01 mean?

Barudan D01 means: The needle bar did not reach the locked position for a colour change. The source points to the colour-change lock sensor or a mechanical bind; rotate the assembly by hand first, and do not force a bind. It is an error code and should be cleared before production.

How do I clear Barudan D01?

Start with: Color Change Lock sensor is not engaged or not working properly. Then: Manually rotate the Color change assembly so the sensor plate engages the Lock sensor and retry. Then: If still a problem look to see if the Sensor LED is working.

When should I call a technician for Barudan D01?

If the code returns after the checks above, or the machine develops a new noise, vibration, or thread break, call a technician.

Source: Barudan America — XS/XY Error Messages. Barudan XS/XY series error messages. Verify against your exact model and manual.

Corrections: if this page is wrong for your model, keep the source link and the model/serial number. The correction process is described in Method & disclaimer.